Measured parameter: TEMP, ECG, NIBP, SpO2

Applications: clinical, transport

Configuration: portable

Other characteristics: continuous, wireless, with touchscreen

Features
8” color TFT LCD Screen (touch screen optional)
Portable, lightweight and sturdy design
Flexible parameters configuration for different clinical environments
Rechargeable Li-ion Battery (up to 12 hours uninterruptable work)
Big font and font color display setting
Spot-check and continuous monitoring mode
Selectable for Adult, Pediatric and Neonatal patients
Wired/Wireless CMS, support HL7 protocol to HIS
Barcode scanner support
Thermal recorder support
Graphical & tabular trend review
48 hours holographic wave review for each patient (stored in SD card)

Configuration 1
SpO2 + NIBP, Li-ion battery
Optional
Masimo/Nellcor SpO2, Quick Temp, Barcode scanner


Configuration 2
SpO2+NIBP+ECG+TEMP, Li-ion battery

Optional
Masimo/Nellcor SpO2, EtCO2, Quick Temp, Barcode scanner, Thermal Recorder


TEHNICAL SPECIFICATIONS

Display
8” color TFT LCD Screen, resolution: 800 x 600

ECG
Lead type:
3-lead: I, II, III
5-lead: I, II, III, aVR, aVL, aVF, V
Display sensitivity:
2.5 mm/mV (×0.25), 5 mm/mV (×0.5),
10 mm/mV (×1.0), 20 mm/mV (×2.0)
Wave sweep speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
Bandwidth:
Diagnostic mode: 0.05Hz~100Hz
Monitor mode: 0.5Hz~40Hz
Surgery mode: 1Hz~20Hz
Strong filter mode: 5Hz~20Hz CMRR >100dB
Notch: 50/60 Hz notch filter can be set to on or off
Differential input impedance >5 MΩ
Electrode polarization voltage range: ±400 mV
Baseline recovery time <3 s after defibrillation (in monitor and surgery mode)
Calibration signal: 1 mV (peak - peak), accuracy ±3%


RESP
Measurement method: Thoracic electrical
bioimpedance
Measuring lead: Lead I, II
Wave gain: ×0.25, ×0.5, ×1, ×2
Respiratory impedance range: 0.5-5 Ω
Baseline impedance: 500-4000 Ω
Gain: 10 grades
Scan speed: 6.25 mm/s, 12.5 mm/s, 25 mm/s


TEMP
Measurement method: Thermistor
Measuring range: 5~50 °C (41~122 °F)
Resolution: 0.1 °C
Measurement accuracy: ±0.1 °C


Recorder (optional)
Built-in, Thermal dot array
Horizontal resolution: 16 dots/mm (25 mm/s paper speed)
Vertical resolution: 8 dots/mm
Paper speed: 25 mm/s, 50 mm/s
Number of waveform channels: 3


NIBP
Measurement method: Automatic
oscillometric method
Operating mode: Manual, automatic,
continuous
Measurement unit: mmHg/kPa selectable
Typical measurement time: 20~40 s
Measurement type: Systolic, Diastolic, Mean
Measurement range (mmHg)
Range of Systolic pressure:
Adult 40-270
Pediatric 40-230
Neonatal 40-135

Range of Diastolic pressure:
Adult 10-210
Pediatric 10-150
Neonatal 10-100
Range of Mean pressure:
Adult 20-230
Pediatric 20-165
Neonatal 20-110

Measurement accuracy
Maximum average error: ±5 mmHg
Maximum standard deviation: 8 mmHg
Resolution: 1 mmHg

Interval: 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120,
180, 240, 480 minutes
Overpressure protection: Software and
hardware, double safety protection
Cuff pressure range: 0-280 mmHg


Standard SpO2
Measurement range: 0-100%
Resolution: 1%
Accuracy: ±2% (70-100%, Adult/Pediatric); ±3% (70-100%, Neonate); 0-69%, unspecified
Refreshing Rate: 1s

Masimo SpO2 (optional)
Measurement range: 0-100%
Resolution: 1%
Accuracy:
±2% (70-100%, Adult/Pediatric), non-motion, low
±3% (70-100%, Neonate, non-motion);
±3% (70-100%, motion);
0-69%, unspecified
Refreshing Rate: 1s


Infrared Ear Thermometer (optional)
Displayed range: 34~42.2 °C (93.2~108 F°)
Operation ambient temperature range:
10~40 °C (50~104 °F)
Accuracy for displayed temperature range:
≥35 °C (95.9 °F) ~ ≤42.2 °C (107.6 °F) range ±0.2 °C (0.4 °F)
<35 °C (95.9 °F) ~ ≥34 °C (93.2 °F) range ±0.3 °C (0.5 °F)


Phasein IRMA™ Sidestream CO2 (optional)
Warm-up time: Full accuracy within 10 seconds
Sampling flow rate: 50 ml/min (+/-10/min)
Accuracy: ± (0.2% +2% of the reading)
Measurement Range: 0 -15%
Rise time: 200 ms, typical at 50 ml/min flow rate
Total response time: within 3 seconds
(with 2m Momoline sampling line)
AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath


Phasein IRMA™ Mainstream CO2 (optional)
Measurement Range: 0-15%
Warm-up time: Full accuracy within 10 seconds
Accuracy: ± (0.2% +2% of the reading)
AWRR Range: 0-150 bpm
AWRR Accuracy: ±1 breath


Operation Environment
Power: AC 100-250 V, 50/60 Hz
Temperature: 0-40 °C
Humidity: 15-85%
Patient Range: Adult, Pediatric, Neonate


Va rugam sa ne contactati pentru oferta de pret!